Showing 13–24 of 28 results

Gas Sensors

MQ-4 Module (Methane ,CNG Gas Sensor)

129.80 (Inc. GST)
110.00 (+18% GST Extra)

Specifications:

  • Sensor Type Semiconductor
  • Power requirements: VCC – 5V±0.1
  • DO output: TTL digital 0 and 1 (0.1 and 5V)
  • AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
  • Detection Gas: Natural gas/Methane
  • Detection Concentration: 200-10000ppm (Natural gas / Methane)
  • Interface: 1 TTL compatible input (HSW), 1 TTL compatible output (ALR)
  • Heater consumption: less than 750mw
  • Operating temperature: 14 to 122 °F (-10 to 50°C)
  • RH Related humidity less than 95%Rh
  • O2 Oxygen concentration is 21% (standard condition) – Oxygen concentration can affect sensitivity
  • Load resistance: 20KΩ
  • Sensing Resistance Rs: 10KΩ- 60KΩ (1000ppm CH4)
  • Preheat time:Over 24 hour
  • Standard Encapsulation Bakelite, Metal cap

MQ-5 Methane LPG Liquid Propane Gas Sensor Module

108.56 (Inc. GST)
92.00 (+18% GST Extra)

Specifications :

  • Detecting Concentration: 300 to 10000 ppm
  • Input Voltage: 5 VDC
  • Power: 150 mA
  • Digital Output Voltage: TTL digital 0 and 1 (0.1 V and 5 V)
  • Analog Output Voltage (relatively clean): 0.1 V to 0.3 V
  • Analog Output Voltage (highest concentration): 4 V

MQ-6 – LPG Propane Gas Sensor

153.40 (Inc. GST)
130.00 (+18% GST Extra)

Specifications:

  1. Model No: MQ-6
  2. Concentration: 300-10000ppm
  3. Circuit voltage: 5V±0.1
  4. Heating voltage: 5V±0.1
  5. Load resistance: 20KΩ

MQ-6 Module (LPG, Ethenol steam, Smoke Interference)

89.00 (Inc. GST)
75.42 (+18% GST Extra)

Specifications:

  • Operating Voltage is +5V
  • Can be used to detect LPG or Butane gas
  • Analog output voltage: 0V to 5V
  • Digital Output Voltage: 0V or 5V (TTL Logic)
  • Preheat duration 20 seconds
  • Can be used as a Digital or analog sensor
  • The Sensitivity of Digital pin can be varied using the potentiometer

MQ-7 Module (Carbon Monoxide Gas Sensor)

140.42 (Inc. GST)
119.00 (+18% GST Extra)

Specifications :

  • circuit voltage: 5V±0.1
  • Heating voltage (high): 5V±0.1
  • Heating voltage (low): 1.4V±0.1
  • Load resistance: Adjustable
  • Heating resistance: 33Ω±5%
  • Heating time (high): 60±1 seconds
  • Heating time (low): 90±1 seconds
  • Heating consumption: About 350mW
  • Using temperature: -20°C-50°C
  • Storage temperature: -20°C-50°C
  • Relative humidity: Less than 95%RH
  • Oxygen concentration: 21%(stand condition) the oxygen concentration can affect the sensitivity characteristic

MQ-8 Module (Hydrogen Gas Sensor)

159.30 (Inc. GST)
135.00 (+18% GST Extra)

Specifications:

  1. Power supply needs: 5V
  2. Interface type: Analog, Digital
  3. High sensitivity to Hydrogen (H2)
  4. Small sensitivity to alcohol, LPG,cooking fumes
  5. Stable and long life
  6. Size: 32x20mm
  7. Circuit voltage: 5V±0.1
  8. Heating voltage: 5V±0.1
  9. Load resistance: 10KΩ
  10. Heater resistance: 31±5%
  11. Heating consumption: less than800mW
  12. Using Temperature: -10°C-50°C
  13. Storage Temperature: -20°C-70°C
  14. Related humidity: less than 95%Rh
  15. Oxygen concentration: 21%(standard condition)Oxygen concentration can affect sensitivity

MQ-9 Carbon Monoxide, Methane and LPG Gas Sensor Module

159.30 (Inc. GST)
135.00 (+18% GST Extra)

Specifications:

  • Input voltage: DC 5V
  • Power: 150mA
  • DO output: TTL digital 0 and 1 (0.1 and 5V)
  • O output: 0.1-0.3V (relatively clean), the highest concentration voltage is about 4V.
  • Suitable for home or factory gas leakage monitoring devices.
  • Have better sensitivity to Carbon Monoxide, Methane and LPG Gas.
  • High quality dual-panel design, with power indicator and TTL signal output instructions.
  • DO switching signal (TTL) output and AO analog signal output.
  • TTL output valid signal is low. (When the output low signal is on, it can be directly connected micro-controller or relay module.)
  • Analog output voltage: the higher concentration, the higher voltage.

MQ2 Flammable Gas and Smoke Sensor

80.00 (Inc. GST)
67.80 (+18% GST Extra)

Specifications:

•    Operating Voltage: 4.5V to 5V DC.
•    High sensitivity to smoke and flammable gasses
•    Good sensitivity to Combustible gas in wide range
•    Interface type: Analog
•    Long life and low cost

MQ3 Sensor Only

135.70 (Inc. GST)
115.00 (+18% GST Extra)

Features:

  1. Power requirements: 5 VDC @ ~165 mA (heater on) / ~60 mA (heater off)
  2. Current Consumption: 150mA
  3. Operating temperature: 14 to 122 °F (-10 to 50°C)
  4. It has a long service life and reliable stability.
  5. DO output: TTL digital 0 and 1 ( 0.1 and 5V)
  6. AO output: 0.1- 0.3 V (relative to pollution), the maximum concentration of a voltage of about 4V

MS-1100 VOC Gas Sensor Module

998.99 (Inc. GST)
846.61 (+18% GST Extra)

Specifications:

  • The heating voltage:5V+/-2%
  • Working current:100mA (max)
  • The circuit voltage:
  • Sensitivity:>3%
  • Response time:<5s (preheat 3-5 minutes)
  • Response time:>10s
  • The component power consumption: =<430mW
  • Working temperature:-10~60 celsius (nominal temperature 20 celsius)
  • Humidity:90%RH (nominal humidity 65%RH

Ozone Gas Sensor 0~100PPM 0-5V Output

12,390.00 (Inc. GST)
10,500.00 (+18% GST Extra)

Features:

  1. The o3 sensor adopts a high-sensitivity gas detection probe imported from the United States and uses a high-performance signal acquisition circuit, which can accurately measure the PPM-level O3 concentration, with stable signal and high accuracy.
  2. Provide 0-5V output signals.
  3. The o3 sensor adopts a wall-mounted waterproof shell, which is easy to install and has a high degree of protection.
Sold out

Ozone Gas Sensor 0~10PPM 0-5V Output

11,210.00 (Inc. GST)
9,500.00 (+18% GST Extra)

Features:

  1. The o3 sensor adopts a high-sensitivity gas detection probe imported from the United States and uses a high-performance signal acquisition circuit, which can accurately measure the PPM-level O3 concentration, with stable signal and high accuracy.
  2. Provide 0-5V output signals.
  3. The o3 sensor adopts a wall-mounted waterproof shell, which is easy to install and has a high degree of protection.