Gas
6 Pin Universal Gas Sensor Socket
6 Pin Universal Gas Sensor Socket6 Pin Universal Gas Sensor Socket
6 Pin Universal Gas Sensor SocketFeatures:
- It is 6 pins plastic socket, to match with semiconductor sensor use.
- It could be soldered on gas alarm pcb board directly, then insert semiconductor sensor onto it.
- It is more convenient than solder sensor directly on the pcb.
₹1,350.00Add to cart
AC220V 500mg Ozone Generator Ozone Water Air Clean Sterilizer Ozonizer Purifier DIY
AC220V 500mg Ozone Generator Ozone Water Air Clean Sterilizer Ozonizer Purifier DIYAC220V 500mg Ozone Generator Ozone Water Air Clean Sterilizer Ozonizer Purifier DIY
AC220V 500mg Ozone Generator Ozone Water Air Clean Sterilizer Ozonizer Purifier DIYSpecifications :
- Power: 10 W (approx)
- Input voltage: AC 220 V
- Working frequency : 3khz
- Current consumption:<0.3 A
- Ozone output capacity : 500 MG/HR
₹1,350.00Add to cart
Compact Optical Dust Sensor module – GP2Y1010AU0
Compact Optical Dust Sensor module – GP2Y1010AU0Compact Optical Dust Sensor module – GP2Y1010AU0
Compact Optical Dust Sensor module – GP2Y1010AU0Grove Dust Sensor Air Quality
Grove Dust Sensor Air QualityGrove Dust Sensor Air Quality
Grove Dust Sensor Air Quality₹2,100.00Add to cart
MQ-131 Ozone Gas Sensor
MQ-131 Ozone Gas SensorMQ-131 Ozone Gas Sensor
MQ-131 Ozone Gas SensorFeatures:
- with the signal light indicates the output
- the dual signal output (analog output, and TTL-level output)
- TTL output valid signal is low; (low output signal light, can be accessed by the microcontroller IO port)
- the analog output increases with the concentration, the higher the voltage the higher the concentration
- the ozone gas with high sensitivity (detection concentration range 10PPB-2PPM Ozone)
- with a long life and reliable stability
- Fast response characteristics
- with mounting holes to facilitate fixed installation
- the probe can plug design for easy testing.
₹2,100.00Add to cart
MQ-135 Module (Ammonia, Sulphide and Benzene Gas Sensor)
MQ-135 Module (Ammonia, Sulphide and Benzene Gas Sensor)MQ-135 Module (Ammonia, Sulphide and Benzene Gas Sensor)
MQ-135 Module (Ammonia, Sulphide and Benzene Gas Sensor)Specifications:
- Sensitivity to Ammonia, Sulphide and Benzene steam
- Sensitive for benzene, alcohol, smoke
- Fast response and recovery
- Adjustable sensitivity
- Signal output indicator
- Output voltage boosts along with the concentration of the measured gases increases
MQ-2 Modules
MQ-2 ModulesMQ-2 Modules
MQ-2 ModulesSpecifications :
1. Good sensitivity to Combustible gas in a wide range
2. High sensitivity to LPG, Propane, and Hydrogen
3. Long life and low cost
4. Simple drive circuit
5. Can be used as a Digital or analog sensor
6. The Sensitivity of Digital pin can be varied using the potentiometer
7. Can be used to Measure or detect LPG, Alcohol, Propane, Hydrogen, CO and even methan
MQ-3 Module (Alcohol Gas Sensor)
MQ-3 Module (Alcohol Gas Sensor)MQ-3 Module (Alcohol Gas Sensor)
MQ-3 Module (Alcohol Gas Sensor)Secifications:
- Sensitive to alcohol, ethanol
- Fast response and recovery
- Adjustable sensitivity
- Signal output indicator
- Analog and level signal output.
- The carbon monoxide detection with better sensitivity.
- Has a long service life and reliable stability.
- Output voltage boosts along with the concentration of the measured gases increases
MQ-4 Module (Methane ,CNG Gas Sensor)
MQ-4 Module (Methane ,CNG Gas Sensor)MQ-4 Module (Methane ,CNG Gas Sensor)
MQ-4 Module (Methane ,CNG Gas Sensor)Secifications:
1. Detecting range: 300~10000ppm
2. Signal output indicator
3. Dual Signals output (analog output and TTL output)
4. TTL output signal is low level, allows to connect with SCM directly
5. Analog output 0~5V voltage
6. High sensitivity
7. Long working lifetime and stable performance
8. Quick response and recovery
MQ-5 Module (LPG Gas Sensor)
MQ-5 Module (LPG Gas Sensor)MQ-5 Module (LPG Gas Sensor)
MQ-5 Module (LPG Gas Sensor)Specifications :
1. High sensitivity to LPG, natural gas, town gas.
2. Small sensitivity to alcohol, smoke.
3. Stable and long life.
4. Simple drive circuit.
5. Fast response.
MQ-6 Module (LPG, Ethenol steam, Smoke Interference)
MQ-6 Module (LPG, Ethenol steam, Smoke Interference)MQ-6 Module (LPG, Ethenol steam, Smoke Interference)
MQ-6 Module (LPG, Ethenol steam, Smoke Interference)Secifications:
- Operating Voltage: 5V DC
- Indication of the signal output
- Dual signal output (analog output, and TTL level output)
- 0 ~ 5V analog output voltage, the higher the concentration, the higher the voltage
- High sensitivity to hydrogen
- Can be resistant to ethanol steam, LPG (petroleum), smoke interference
- Has a long life and reliable stability
- Fast response and recovery characteristics
MQ-7 Module (Carbon Monoxide Gas Sensor)
MQ-7 Module (Carbon Monoxide Gas Sensor)MQ-7 Module (Carbon Monoxide Gas Sensor)
MQ-7 Module (Carbon Monoxide Gas Sensor)Features :
- Operating voltage: DC 5 V.
- The analog output voltage, the higher the concentration the higher the voltage.
- The carbon monoxide detection with better sensitivity.
- With a long service life and reliable stability.
- Rapid response and recovery characteristics.
- Range: 10 to 1000 ppm.
MQ-8 Module (Hydrogen Gas Sensor)
MQ-8 Module (Hydrogen Gas Sensor)MQ-8 Module (Hydrogen Gas Sensor)
MQ-8 Module (Hydrogen Gas Sensor)Secifications:
- Using high-quality dual-panel design, with power indicator and TTL signal output instructions.
- The switching signal having a DO (TTL) output and analog output AO.
- TTL output valid signal is low.
- The higher the voltage, the concentration of the analog output voltage is higher.
- A hydrogen gas detection with good sensitivity.
- Has a long life and reliable stability
MQ-9 Module (Methane & CO Gas Sensor)
MQ-9 Module (Methane & CO Gas Sensor)MQ-9 Module (Methane & CO Gas Sensor)
MQ-9 Module (Methane & CO Gas Sensor)Specifications:
- Good sensitivity to CO/Combustible Gas
- High sensitivity to Methane, Propane, and CO
- Long life and low cost
- Simple drive circuit
- Input voltage: DC 5±0.2V
- Current Consumption: 150mA
MQ2 Flammable Gas and Smoke Sensor
MQ2 Flammable Gas and Smoke SensorMQ2 Flammable Gas and Smoke Sensor
MQ2 Flammable Gas and Smoke SensorSpecifications:
• Operating Voltage: 4.5V to 5V DC.
• High sensitivity to smoke and flammable gasses
• Good sensitivity to Combustible gas in wide range
• Interface type: Analog
• Long life and low cost
MQ3 Sensor Only
MQ3 Sensor OnlyMQ3 Sensor Only
MQ3 Sensor OnlyFeatures:
- Power requirements: 5 VDC @ ~165 mA (heater on) / ~60 mA (heater off)
- Current Consumption: 150mA
- Operating temperature: 14 to 122 °F (-10 to 50°C)
- It has a long service life and reliable stability.
- DO output: TTL digital 0 and 1 ( 0.1 and 5V)
- AO output: 0.1- 0.3 V (relative to pollution), the maximum concentration of a voltage of about 4V
Ozone Gas Generator
Ozone Gas GeneratorOzone Gas Generator
Ozone Gas GeneratorOverview:
input voltage | DC5v |
Working current | 450ma–600ma |
power | 2W–3W |
Ozone concentration | 100mg/H |
size | 42*25*21 |
weight | 39g |
working temperature | ‘-10°–+55° |
Working humidity | 10%–85% |
insulation resistance | Power cord pair housing≧40MΩ |
PM2.5 GP2Y1010AU0F Dust Smoke Particle Sensor
PM2.5 GP2Y1010AU0F Dust Smoke Particle SensorPM2.5 GP2Y1010AU0F Dust Smoke Particle Sensor
PM2.5 GP2Y1010AU0F Dust Smoke Particle SensorFeatures:
- Power supply voltage: DC5 ± 2V
- Sensitivity: 0.5V / (0.1mg / m3)
- The minimum detection level of particles: 0.8 m
- Clean air voltage: 0.9V typ.
- Low consumption current (Icc: MAX. 20 mA)
- The presence of dust can be detected by the photometry of only one pulse
- Enable to distinguish smoke from house dust